Nashik
+918830681945

'stainless steel tank for water purifier'

Items tagged with 'stainless steel tank for water purifier'

product image
A 250 LPH (liters per hour) RO plant falls into the Commercial or Industrial RO Plant category, designed for medium-scale applications in businesses, schools, hotels, and factories that require a significant and consistent supply of purified water. These systems utilize a single or multi-membrane setup to produce up to 250 liters of pure water per hour, removing dissolved solids, chemicals, and other impurities from raw water.

A typical 250 LPH RO plant specification includes a multistage filtration system, a high-pressure pump, and RO membranes to process water. Key components are the Feed Pump, Pressure Sand Filter (PSF), Activated Carbon Filter (ACF), and a Micron Cartridge Filter (5-micron) before the high-pressure pump and RO membranes. A control panel with necessary switches, pressure gauges, and flow meters is also included, along with options for automatic flushing to extend membrane life. Key Components & Specifications Raw Water Feed Pump: A pump (e.g., Kirloskar, Sumo) to provide initial water flow to the pre-filters. Pre-Filtration: Pressure Sand Filter (PSF): Removes suspended solids using graded pebbles and sand in an FRP tank. Activated Carbon Filter (ACF): Adsorbs dissolved organic compounds and chlorine. Cartridge/Micron Filter: Removes finer particles, typically down to 5 microns, before the high-pressure pump to protect the membranes. High-Pressure Pump: A multistage, centrifugal pump (e.g., CRI, Sumo) that raises the water pressure to force it through the RO membranes. RO Membranes & Housing: These are the heart of the system, separating purified water from dissolved salts. They are typically housed in a pressure vessel made of FRP or stainless steel. Dosing Pump: A pump for precise dosing of antiscalant chemicals to prevent scaling on the membrane surface. Control System: Control Panel: Manages the operation of the pumps and valves. Pressure Gauges: Monitor pressure throughout the system. Rotameter/Flow Meter: Measures the flow rate of purified water. Auto Flush System: An optional feature that uses a timer to automatically flush the membranes to prolong their life. Plumbing & Skid: All components are mounted on a robust skid, often made of stainless steel for durability and hygiene. Typical Performance Product Water Flow Rate: 250 liters per hour. Input TDS: Can handle TDS levels up to approximately 2000 ppm. Recovery Rate: Typically 50-60%, depending on the system's design and raw water quality. Power Supply: Often single-phase.

Send Message
product image
150 LPH RO PLANT

A typical 150 LPH (Liters Per Hour) RO plant includes a flow rate of 150 LPH, uses a stainless steel or FRP (Fiber-Reinforced Plastic) construction, and features 5-8 purification stages, such as pre-filters, carbon filters, RO membranes, and a post-carbon filter. Key components are a heavy-duty booster pump, auto-shutoff, and a TDS controller, with filtration suitable for input water TDS up to 2000 ppm. The system can be semi-automatic or fully automatic, with optional UV and Ultrafiltration (UF) stages for enhanced purification. Core Specifications Flow Rate: 150 Liters Per Hour (LPH). Construction: Primarily Stainless Steel (SS 304 or SS 316) or FRP. Input Water TDS: Designed for water with TDS levels typically above 1000 ppm, often up to 2000 ppm or higher. Automation: Can be manual, semi-automatic, or fully automatic, depending on the model. Filtration Stages A standard 150 LPH RO plant includes multiple stages: Pre-Filters: Sediment filters (e.g., 5-micron) to remove large particles like dirt and rust. Activated Carbon Filter: Removes chlorine, organic impurities, and odor. RO Membrane: Removes dissolved solids, heavy metals, and other contaminants. TDS Controller: Adjusts the taste by maintaining essential minerals in the purified water. Post Carbon Filter: Improves the final taste and odor of the water. Optional Enhancements UV Sterilization Unit: Destroys microorganisms like bacteria and viruses. Ultrafiltration (UF): Further enhances water clarity and taste. Other Components Booster Pump: A high-pressure pump to provide the necessary pressure for the RO membranes. Auto Shut-OFF/Flushing: Features to automatically shut off the system when the tank is full and flush the membranes to extend their life. Piping: Typically includes stainless steel or UPVC piping for the system's connections. 150 LPH RO Plant, Stainless Steel - IndiaMART 150 LPH RO Plant, Stainless Steel * RO Capacity. 150 LPH. * Material. Stainless Steel. * Automation Grade. Manual. * Usage/Applic... IndiaMART TECHNICAL SPECIFICATIONS 150 LPH (SOLAR RO) - GeM REQUIRED. 1. OUTPUT FLOW RATE (LITTERS/HOUR) 150. 2. INLET PRESSURE. MINIMUM INLET PRESSURE (IN KG/ CM2) 1.0. MAXIMUM INLET PRESSU... GeM Best 150 LPH RO Plant | No.1 Industrial ... 150 LPH RO Plant | Industrial RO Water Plant | RO Plant for Business | Best for Office, School, Restaurant, Cafe & Factory Show all

Send Message
product image
A 500 liters per hour (LPH) Reverse Osmosis (RO) plant typically includes components like a raw water pump, multimedia filters (activated carbon and sand filters), a high-pressure pump, RO membranes, and a control panel. Specifications vary by manufacturer, but generally, these plants are designed for brackish or slightly contaminated water, with a maximum Total Dissolved Solids (TDS) level of around 2000-3000 ppm

A 500 liters per hour (LPH) Reverse Osmosis (RO) plant typically includes components like a raw water pump, multimedia filters (activated carbon and sand filters), a high-pressure pump, RO membranes, and a control panel. Specifications vary by manufacturer, but generally, these plants are designed for brackish or slightly contaminated water, with a maximum Total Dissolved Solids (TDS) level of around 2000-3000 ppm. Here's a more detailed breakdown of the components and specifications: 1. Raw Water Pump: Purpose: To draw water from the source and feed it into the filtration system. Capacity: Often around 0.5 HP, with a head of 15 meters (or more), according to some commercial RO plant providers. Make: Kirloskar or Crompton Greaves are common brands, according to a technical document. 2. Multimedia Filters (Activated Carbon and Sand Filters): Purpose: To remove suspended solids, dirt, iron, and chlorine, protecting the RO membrane from fouling. Media: Typically include activated carbon and sand, according to some commercial RO plant providers. Configuration: Often housed in FRP (Fiber Reinforced Plastic) vessels, with multi-port valves for backwashing. 3. High-Pressure Pump: Purpose: To pressurize the water to overcome the osmotic pressure of the RO membrane, ensuring efficient water filtration. Capacity: Typically 1.0-2.0 kW, with a flow rate of 3500 liters per hour and a head of 125 meters. Make: CRI or Sumo are common brands, according to some commercial RO plant providers. 4. RO Membranes: Purpose: To remove dissolved salts, minerals, and other impurities from the water. Type: Typically thin-film composite (TFC) or polyamide membranes. Size: 4040 (4-inch diameter, 40-inch length) is a common size for commercial RO plants, according to some commercial RO plant providers. Number: 500 LPH systems usually have two membranes in a single housing. 5. Control Panel: Purpose: To control and monitor the operation of the RO plant, including pressure, flow rate, and other parameters. Automation: Can be semi-automatic or fully automatic, depending on the system. 6. Other Components: Micron filter: To remove finer suspended particles. Dosing pump: To add chemicals for pre-treatment or cleaning. Pressure gauges: To monitor pressure at various points. Flow meters: To measure the flow rate of water. RO membrane housing: Typically made of stainless steel or FRP. 7. Recommended Conditions: Inlet TDS: Up to 3000 ppm, according to some commercial RO plant providers.

Send Message

Still searching for
stainless steel tank for water purifier?